6- Electric panels for sewage pumps

Electric panels with direct starter for the control and protection of sewage pumps. Mounted in IP65 or IP66 electric box. It includes MCCB, motor protections, man-stop-automatic selector, 2-3-4-5 float level inputs, pump alternation and light indicators.

RBF2D1

RBF2D1

Electric control panel for 1 pump with direct starter. Mounted in IP65 electric box. 2-3-4-5 float level input control. Motor protection up to 16A 230V II. Light indicators in panel. MCCB total protection. Man-stop-aut selector for each pump. Light indicators start and reset. Pump alternation.
Dimensions: 450x300x142mm.

RBF3D1

RBF3D1

Electric control panel for 1 pump with direct starter. Mounted in IP65 electric box. 2-3-4-5 float level input control. Motor protection up to 10A 400V III. Light indicators in panel. MCCB total protection.Man-stop-aut selector for each pump.
Light indicators start and reset. Pump alternation.
Dimensions: 450x300x142mm.

RBF2D2

RBF2D2

Electric control panel for 2 pumps with direct starter. Mounted in IP65 electric box. 2-3-4-5 float level input control. Motor protection up to 16A 230V II. Light indicators in panel. MCCB total protection. Man-stop-aut selector for each pump.
Light indicators start and reset. Pump alternation.
Dimensions: 450x300x142mm.

RBF3D2

RBF3D2

Electric control panel for 2 pumps with direct starter. Mounted in IP65 electric box. 2-3-4-5 float level input control. Motor protection up to 10A 400V III. Light indicators in panel. MCCB total protection. Man-stop-aut selector for each pump. Light indicators start and reset. Pump alternation.
Dimensions: 450x300x142mm.

RBFX2D1

RBFX2D1

Electric control panel for 1 pump with direct starter. Mounted in IP66 electric box. 2-3-4-5 float level input control. Safe voltage control float level. Motor protection up to 16A 230V II. Light indicators inside box. MCCB total protection. Man-stop-aut selector for each pump. Light indicators start and reset. Pump alternation.
Dimensions: 400x328x140mm.

RBFX3D1

RBFX3D1

Electric control panel for 1 pump with direct starter. Mounted in IP66 electric box. 2-3-4-5 float level input control. Safe voltage control float level. Motor protection up to 10A 400V III. Light indicators inside box. MCCB total protection. Man-stop-aut selector for each pump. Light indicators start and reset. Pump alternation.
Dimensions: 400x328x140mm.

RBFX2D2

RBFX2D2

Electric control panel for 2 pumps with direct starter. Mounted in IP66 electric box. 2-3-4-5 float level input control. Safe voltage control float level. Motor protection up to 16A 230V II. Light indicators inside box. MCCB total protection. Man-stop-aut selector for each pump. Light indicators start and reset. Pump alternation.
Dimensions: 400x328x140mm.

RBFX3D2

RBFX3D2

Electric control panel for 2 pumps with direct starter. Mounted in IP66 electric box. 2-3-4-5 float level input control. Safe voltage control float level. Motor protection up to 10A 400V III. Light indicators inside box. MCCB total protection. Man-stop-aut selector for each pump. Light indicators start and reset. Pump alternation.
Dimensions: 400x328x140mm.

A2B

A2B

Electronic control A2B to control priority change relay of 2 pumps. Leds: pump 1 on, pump 2 and 230V supply. Inputs: priority change of 2 pumps and pumps on. Outputs: relay 1 and relay 2 8A/250V. Voltage supply: 230V.
Dimensions: 70x90x70mm (4 modules DIN).

A3B

A3B

Electronic control A3B to control priority change relay of 2 pumpsLeds: pump 1 on, pump 2 and alarm. Inputs: priority change of 2 pumps, pumps on, level alarm and thermal alarm. Outputs: relay 1 and relay 2 8A/250V. Voltage supply: 230V.